What was found
SHUT DOWN THE HELICOPTER AT ICY, WHEN ATTEMPTING TO RESTART THE IGNITER WAS FIRING BUT THE COMPRESSOR WAS NOT TURNING. WENT BACK THROUGH THE CHECKLIST, ON THE SECOND ATTEMPT THE SAME THING HAPPENED, WITH MAINTENANCE PRESENT ON THE THIRD ATTEMPT THE COMPERSSOR WAS TURNING AND THE FUEL LIT OFF BUT PRIOR TO REACHING FLIGHT IDEL 30-40 PERCENT THE FLAME WENT OUT. MAINTENANCE REMOVED AND REPLACED THE STARTER GENERATOR, INSPECTED THE COMPRESSOR FOR FOD, INSPECTED FUEL NOZZLE, AIR LINES AND THE FUEL. GROUND RUN CHECK COMPLIED WITH AND STARTED THREE TIMES WITH THE PILOT RESTARTING THE LAST START. NO OTHER DEFECTS FOUND AND STARTING TIME IS 25-35 SECONDS. (M)