Service difficulty report · Housing

Difficulty date
September 19, 2004
Submitted
February 25, 2005
Operation
General aviation
Part
Housing
Part number
ALK1242AAS2
Condition
Misrepaired
Location
Alternator
Component
Alternator · Electrosys
Component part number
ALX9524R
Stage of operation
IN
How discovered
V
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

IN PREPARING ALTERNATOR FOR INSTALLATION. CLOSE INSPECTION REVEALED THAT LIGHT PRESSURE ON NEGATIVE DIODE CAUSED DIODE TO BECOME UNSEATED FROM BORE IN HOUSING. INSPECTION OF BORE SHOWED THAT THE BORE WAS OVERSIZED AND HAD BEEN PAINTED DURING OVERHAUL. DIODE BORE DIMENSION (.499 INCH +/- .001 INCH) IS CRITICAL TO RELIABLE OPERATION OF THE ALTERNATOR. (THE DIODES RELY ON A PRESS FIT TO MAINTAIN ADEQUATE HEAT DISSIPATION AND CURRENT FLOW AND SHOULD NOT BE INSTALLED IN A BORE THAT HAS PAINT OR ANY OTHER ELECTRICALLY RESISTIVE MATERIAL IN IT.) THIS FAILURE IS EXACTLY THE SAME AT THE UNIT THAT WAS BEING REPLACED, HAVE SEEN NUMEROUS OTHER (LOOSE DIODES), RETURNED TO FACTORY FOR WARRANTY.