What was found
RECEIVED EVACUATION SLIDE FOR RECERTIFICATION. DURING DISASSY EACH FRANGIBLE LINKS (PN C19347-101, 4EA, PN C19347-102, 1EA, PN C19347-105, 2EA) WERE FOUND WITH (4) STRANDS OF BLACK NYLON THREAD SECURING EACH HALF OF FRANGIBLE LINK TOGETHER. FRANGIBLE LINKS WERE PREVIOUSLY BROKEN, REUSED BY SECURING HALVES TOGETHER WITH BLACK NYLON THREAD. NORMAL OR UNUSED FRANGIBLE LINKS ARE 2 LOOPS SECURED WITH STRANDS OR BRAKING WIRES, HAVING A SPECIFIC BREAKING STRENGTH WHICH ARE COVERED WITH HEAT SHRINK TUBING. IF SLIDE WAS DEPLOYED WITH MODIFIED FRANGIBLE LINKS, SLIDE WOULD POSSIBLY EXTEND RAPIDLY, TOE END OF SLIDE WOULD EXTEND UNDER THE AC. ONCE FRANGIBLE LINKS ARE BROKEN, REQUIRED TO BE REPLACED WITH NEW (2 OF 3)