What was found
DURING ROUTINE MAINTENANCE, FOUND BATTERY POS CABLE BEING CHAFED ON CONTROL CABLE TURNBUCKLE IT CAME IN CONTACT WITH. THE SAWING MOTION OF THE TURNBUCKLE ALMOST WORE THRU THE BATTERY CABLE INSULATION JACKET. THE CABLE WAS REROUTED (REPOSITIONED) AT LAST 100 HR FOR THE SAME REASON. THE CABLE HAS TAKEN A SET AND KEEPS RETURNING TO ITS ORIGINAL BEND CONFIGURATION. RECOMMEND SHORTENING THE CABLE AND CRIMPING THE TERMINAL ENDS 90 DEGREES TO THE LAY OF THE CABLE. (K)