AFT PIT FUSELAGE FRAME INNER FLANGE IS DENTED AT BS 1400, STR 25L. *S/D* DAMAGE DUE TO TYPICAL CARGO LOADING IN AFT PIT. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE REPAIR.