What was found
FOUND WIRES FROM K114 RELAY CHAFING ON CURRENT SENSING TRANSFORMER BRACKET. FOUND HARNESS ARCING AND SMOLDERING. P-34 ELECTRICAL POWER PANEL, WIRE W1134-0024-8 FROM RELAY K114 TERMINAL C1, WAS FOUND CHAFFED AND ARCING ON THE SUPPORT BRACKET OF CURRENT TRANSFORMER T116. REPLACED WIRE W1134-0024-8 FROM RELAY K114 TERMINAL C1 TO C/B C305 AND WIRE W1134-0009-8 FROM RELAY K114 TERMINAL C1 TO C/B C306 (WIRES ARE CRIMPED TOGETHER ON THE SAME TERMINAL AT K114 -C1).