What was found
WITH FLAPS UP (CRUISE CONFIG), THE L/E FLAPS TRANSIT LIGHT IS ON AND ANNUNCIATOR FLAP NR 2 TRANSIT LIGHT IS ON INTERMITTENTLY. THE L.E. FLAPS TRANSIT LIGHT AND FLAP NR 2 ANNOUNCIATOR LIGHT WERE ILLUMINATED BECAUSE OF A FAULTY NR 2 SLAT SENSOR (PN 10-6222-1, PCN 420-2108). THE SUBJECT SENSOR WAS REMOVED AND REPLACED PER MM 27-88-11/401. CURRENT MAINTENANCE PROGRAM: ON CONDITION CURRENTLY THE ARE NO UNUSUAL MAINTENANCE TRENDS ATTRIBUTED TO THIS SENSOR OR EVENT. NO MAINTENANCE PROGRAM CORRECTIVE ACTION WILL BE GENERATED IN RESPONSE TO THIS EVENT.