What was found
OVERSIZE HOLES WERE FOUND COMMON TO SHEAR TIE AT STA 727D BETWEEN S23R, S24R AND THE SKIN. FUSELAGE FRAME SHEAR TIE WAS REPLACED AND REINFORCED PER SRM 51-00-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OVERSIZE HOLES WERE FOUND COMMON TO SHEAR TIE AT STA 727D BETWEEN S23R, S24R AND THE SKIN. FUSELAGE FRAME SHEAR TIE WAS REPLACED AND REINFORCED PER SRM 51-00-04.