What was found
STA 211 FRAME WEB WAS CHAFED BEYOND LIMITS BETWEEN STR 15R AND 16R, FRAME WAS ALSO GOUGED BEYOND LIMITS. SPLICED IN NEW SECTION OF WEB REF SRM 51-70-13 FIG 1 AND SPLICED IN NEW FRAME FROM STR 15R TO 17R REF SRM 51-70-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 211 FRAME WEB WAS CHAFED BEYOND LIMITS BETWEEN STR 15R AND 16R, FRAME WAS ALSO GOUGED BEYOND LIMITS. SPLICED IN NEW SECTION OF WEB REF SRM 51-70-13 FIG 1 AND SPLICED IN NEW FRAME FROM STR 15R TO 17R REF SRM 51-70-12.