What was found
FRAME HAS A DENT AT STA 1400 BETWEEN STR 26L AND STR 27L, AFT PIT, INBOARD FLANGE. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE TO EXISTING CHORD PER TIMCO REO (EVA) G10828, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME HAS A DENT AT STA 1400 BETWEEN STR 26L AND STR 27L, AFT PIT, INBOARD FLANGE. REPAIRED FRAME FLANGE WITH NESTED J-ANGLE TO EXISTING CHORD PER TIMCO REO (EVA) G10828, REV B.