What was found
CABIN FLOORBEAM CORRODED ON UPPER CAP STA 986.5, RBL 25-45 AT WL 208. MAJOR REPAIR ACP'D PER MM 53-10-95, APPROX 50" SECTION OF UPPER "T" CAP SPLICE TYPE REPAIR SCHEME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM CORRODED ON UPPER CAP STA 986.5, RBL 25-45 AT WL 208. MAJOR REPAIR ACP'D PER MM 53-10-95, APPROX 50" SECTION OF UPPER "T" CAP SPLICE TYPE REPAIR SCHEME.