What was found
FOUND CRACKED SHEAR CLIP IN LOWER RADIUS JUST ABOVE DOOR L2 UPPER SILL, STA 967. FABRICATED CLIP PER 53-00- 07 AND INSTALLED PER SRM 51-40-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CRACKED SHEAR CLIP IN LOWER RADIUS JUST ABOVE DOOR L2 UPPER SILL, STA 967. FABRICATED CLIP PER 53-00- 07 AND INSTALLED PER SRM 51-40-02