What was found
FUSELAGE DENT IS A CRACK 3 - 8 INCHES IN CENTER OF DENT. *S/D* RE-CHECKED DENT WITH HFEC. NO CRACKS FOUND. ACP HFEC INSPECTION EVERY A CHK UNTIL PERMANENT REPAIR INSTALLED NO LATER THEN 05NOV06. ENSURE THAT THERE ARE NO LOOSE FASTENERS IN & ADJACENT TO THE DMG AREA, INSP THE SECURITY OF THE ADJACENT DOUBLER REPAIR FASTENERS AND ADJACENT BUTT SPLICE BETWEEN S-15L AND S-13L. IF DISCREPANCY IS FOUND CONTACT LINE ENGINEER PRIOR TO FURTHER FLIGHT.