What was found
FOUND FLOORBEAM AT STA 947 CORRODED FROM RBL 29 TO RBL 39. BLENDED CORRODED AREA. ACP NDT FOR CRACKS BLEND OUT OF LIMITS. FABRICATED & INSTALLED NESTED ANGLE REPAIR ON AFT SIDE OF FRAME REF. MM 53-10-95.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM AT STA 947 CORRODED FROM RBL 29 TO RBL 39. BLENDED CORRODED AREA. ACP NDT FOR CRACKS BLEND OUT OF LIMITS. FABRICATED & INSTALLED NESTED ANGLE REPAIR ON AFT SIDE OF FRAME REF. MM 53-10-95.