What was found
CABIN FLOORBEAM UPPER CAP HAS A DEEP GOUGE COMING OUT OF FWD HOLE AT STA 520 RBL 24.75. NESTED ANGLE REPAIR INSTALLED PER MM 53-10-95 RPR NR 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM UPPER CAP HAS A DEEP GOUGE COMING OUT OF FWD HOLE AT STA 520 RBL 24.75. NESTED ANGLE REPAIR INSTALLED PER MM 53-10-95 RPR NR 6.