What was found
FWD PIT STA 506 STR 25R INTERCOSTAL WEB HAS CRACK IN VERTICAL FLANGE UPPER END. REMOVED DAMAGE, FABRICATED AND DRILLED UP REPAIR ANGLES, INSTALLED RPR REF SRM 51-70-11 FIG 1 AND SRM 51-40-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT STA 506 STR 25R INTERCOSTAL WEB HAS CRACK IN VERTICAL FLANGE UPPER END. REMOVED DAMAGE, FABRICATED AND DRILLED UP REPAIR ANGLES, INSTALLED RPR REF SRM 51-70-11 FIG 1 AND SRM 51-40-01.