What was found
FOUND STA 1434, RT KEEL BEAM FITTING, SHIM IS MIGRATED. BS 1434, RH KEEL BEAM FITTING, SHIM IS MIGRATED. REMOVED BROKEN SHIM, ACP HEFC INSP OF HOLES AND SPLICE PLATES FOR CRACK, NO CRACK FOUND. MANUFACTURED SOLID SHIM AND REINSTALL. SHIM MIGRATION TYPICALLY CAUSED BY IMPROPER CONTACT SURFACE MATCH OR INADEQUATE TENSION ON FASTENERS.