What was found
EMPENNAGE BS 1040 FRAME AFTSIDE OF WEB GOUGED AT 1B EDGE OF APU BLEED AIR SUPPLY DUCT ACCESS HOLE. *S/D* MAJOR REPAIR: REMOVED DAMAGE. FABRICATED AND INSTALLED DOUBLER REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.