What was found
DENT IS FOUND AT EXTERNAL FUSELAGE SKIN AT STA 677.5, BETWEEN STR 27L & 28L. ACCOMPLISHED HEFC INSPECTION IN DENTED AREA, INTERNAL AND EXTERNAL. NO CRACK IS FOUND. MEASURED DENT: 3.0" X 3.5", Y=.120". ACCOMPLISHED REPAIR PER EN777-53-0020-02 AND UA EVA-60625. REPLACE STR 27L TO 28L SHEAR TIE ANGLE. THE REPAIR IS A CATEGORY B REPAIR REQUIRES VISUAL REINSPECTION 094972 BEGINING AT 30000 CYCLE FROM CURRENT CYCLE COUNT. THE REPETITIVE INSPECTION WILL BE AT INTERVAL 0F 8000 CYCLE THEREAFTER. NOTIFIED SMAC-LINE MAINTENANCE TO REMOVE THE CF ITEM ONCE THE EC IS IMPL EMENTED. THE REPAIR IS FAA APPROVED.