What was found
DENT ON FUSELAGE APPROX STA 370 LT SIDE AT 0500 O'CLOCK POSITION. MEASURES 2"X 1"X .0625". 2.5" FROM LAP JOINT. MAJOR REPAIR: REMOVED DAMAGE AND FASTENERS. FABRICATED AND INSTALLED DOUBLER AND STRUCTURAL FILLERS PER SRM 53-00-01 FIG 201 REPAIR 31.