What was found
FOUND UPPER DECK BS 980 RBL 20-30, FLOOR BEAM ATTACH INTERCOSTAL UPPER CHORD CORROSION. CUT OUT CORROSION AREA REF SRM 53-20-51. INSTALLED FILLER & REPAIR ANGLE REF SRM 53-00-51 FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND UPPER DECK BS 980 RBL 20-30, FLOOR BEAM ATTACH INTERCOSTAL UPPER CHORD CORROSION. CUT OUT CORROSION AREA REF SRM 53-20-51. INSTALLED FILLER & REPAIR ANGLE REF SRM 53-00-51 FIG 201.