Service difficulty report · Battery · Cirrus SR22

Difficulty date
December 18, 2006
Submitted
January 5, 2007
Operation
General aviation
Aircraft
N910JR
Make and model
Cirrus SR22
Aircraft serial
0142
Engine
Cont IO550*
Part
Battery
Condition
Leaking
Location
Elt
Component
Elt
Component part number
E01
Stage of operation
IN
How discovered
9
Nature of condition
K
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING ANNUAL INSPECTION, FOUND BATTERY COMPARTMENT CONTAMINATED BY LEAKAGE FROM D CELLS AND BATTERY TERMINALS CORRODED. BATTERIES FOUND DEAD. BATTERIES WERE INSTALLED MARCH 2004 AND HAVE A EXPIRATION DATE OF MARCH 2008. THE MODEL ELT IS CERTIFIED BY THE MFG TO USE THE BATTERY EXPIRATION DATES FOR SERVICE RATHER THAN A LIMITED CALENDAR TIME SUCH AS THE TYPICAL 24 MONTHS. THIS INSPECTOR HAS RECENTLY FOUND OTHER ELTS OF THE SAME TYPE IN THE SAME CONDITION. RECOMMENDATION THA THE SERVICE LIFE OF THE BATTERIES BE LIMITED TO 24 MONTHS. (K)