What was found
DURING COMPLETION OF MFG PROGRAM PHASE 5 INSPECTION, NOTICEABLE DEPRESSION WAS OBSERVED IN UPPER SURFACE OF LT AND RT WING SKINS IN AREA OF MLG UPLOCK HOOK ASSY ATTACHMENT. DURING COMPLETION OF LANDING GEAR OPERATIONAL CHECK, IT WAS NOTED THAT DEPRESSION ARE SIZE GREW WHILE MLG WAS IN UP AND LOCKED POSITION. USING THE COIN TAP TEST METHOD. CONFORMATION WAS MADE THAT BOTH BONDED PANELS WERE DELAMINATED. IAW TECH SUPPORT, NO DELAMINATION IS ALLOWED ON THESE PANELS. OPTIONS AVAILABLE FOR REMEDY WERE REMOVED AND REPLACED, POSSIBLE REPAIR DEFINITION AND ASSOC 8110 FORM, OR POSSIBLE TEMPORARY REPAIR WITH FLIGHT EXTENSION. (K)