As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING SCHEDULED INSPECTION OF THE AC, THE MECHANIC FOUND THE LT ELEVATOR PITCH TRIM CONTROL CABLE CHAFING ON THE ELEVATOR CABLE PASS THROUGH HOLE LOCATED IN SKIN PN 101-620000-3. THE ELEVATOR CABLE PASS THROUGH HOLE REQUIRED TRIMMING TO ALLOW PROPER CLEARANCE. ADJUSTMENTS TO PASS THROUGH HOLE ACCOMPLISHED IAW IAW MFG. (K)