What was found
CONTROL CABLE, (P/N 0510105-339), FOUND WORN TO REPLACE LIMITS IAW AC43.13-1A, CABLE INSPECTION. CABLE WAS WORN DUE TO CONSTANT CONTACT WITH LANDING GEAR BULKHEAD FAIRLEAD P/N S338-7. IT IS BELIEVED THAT THE HOLE MISALIGNMENT CAUSED THIS CONSTANT CONTACT. CESSNA MAINTENANCE MANUAL DOES NOT CONTAIN ANY (CABLE WEAR) LIMITS OR COMMENTS, ONLY CABLE WIRE BREAKAGE AND CORROSION LIMITS.