As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO PIT, FLOOR STRUCTURE FRAMES AT STA 480 LBL 45.5 AND STA 480 LBL 24.75 ARE BENT AND HAVE PULLED FASTENERS AFT OF STA 480 WEB. [SUP 06-01-07] MAJOR REPAIR ACCOMPLISHED: REMOVED CLIPS AT BOTH WEBS. MFG'D NEW CLIPS AND WEBS AND BEGAN DRILLING AT BOTH LOCATIONS. INSTALLED MFG'D CLIPS AND WEBS WHILE REPAIRING RAILS.