What was found
MAIN BATTERY CHARGER STATUS MSG REPORTED BY CREW. INTERCHANGED MAIN BATTERY AND APU BATTERY PER MM 24-31-01 AND MM 24-31-04. SUSPECT FAULTY CONNECTION, CHARGER TO MAIN BATTERY. EICAS MSG ERASED AND NOW MAIN BATTERY OPERATES NORMALLY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN BATTERY CHARGER STATUS MSG REPORTED BY CREW. INTERCHANGED MAIN BATTERY AND APU BATTERY PER MM 24-31-01 AND MM 24-31-04. SUSPECT FAULTY CONNECTION, CHARGER TO MAIN BATTERY. EICAS MSG ERASED AND NOW MAIN BATTERY OPERATES NORMALLY.