What was found
RTFL DUE TO ALL 4 EFIS SCREENS BLINKING. REMOVED AND CLEANED EFIS FILTER, FANS AND CHECK VALVES . DISCONNECTED DUCTS TO FORWARD OF FLOW SENSOR TO CHECK FOR OBSTRUCTIONS, ALL OK. REPLACED CONTROL RELAY R401, OPERATES NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RTFL DUE TO ALL 4 EFIS SCREENS BLINKING. REMOVED AND CLEANED EFIS FILTER, FANS AND CHECK VALVES . DISCONNECTED DUCTS TO FORWARD OF FLOW SENSOR TO CHECK FOR OBSTRUCTIONS, ALL OK. REPLACED CONTROL RELAY R401, OPERATES NORMAL.