As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT 10 FEET OF FLOOR MOUNTED EMERGENCY ESCAPE PATH LIGHTING IS INOP. FOUND HIGH MOISTURE CONTENT RUNNING THROUGH AFT SECTION OF EEL STRIP. EXPOSED AND DRIED ALL MOISTURE. REPLACED AFT SECTION OF POWER CABLE AND CLEANED LAMP PINS. OP CHECKS OKAY.