Service difficulty report · Sensor · Boeing 757222

Difficulty date
June 10, 2007
Submitted
July 10, 2007
Operation
Air carrier
Aircraft
N550UA
Make and model
Boeing 757222
Aircraft serial
25398
Aircraft time
58,704 hours, 17,086 cycles
Engine
Pwa PW2037
Part
Sensor
Part number
2202450
Condition
Stuck
Location
Cabin Temp
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CABIN TEMPERATURE DIFFICULT TO CONTROL, CANNOT WARM UP THE CABIN & COCKPIT. INSPECTED AND CLEANED CABIN AND FLT DECK TEMP SENSORS AND EVALUATE TEMP CONTROL SYSTEM AS REQUIRED. REPAIRED LARGE AIR LEAK AT JOINT BETWEEN ACM AND PREHEATER IN LT PACK. REPLACED RT PACK AC COMP OUT SENSOR AND RT PACK TEMP SENSOR PACK OUT TEMPS NOW WITHIN LIMITS. DURING T/S FOUND RT PACK STUCK IN LOW FLOW.