As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PRIOR TO DEPARTURE FUEL SEEP EVIDENT ON RIGHT WING BETWEEN T/E FLAP CANOE FAIRINGS 7 & 8, NR 4 MAIN FUEL TANK. TANK ACCESS PANEL 2ND OUTBOARD FROM STICK 21 LOCATION. [07-31-07] REMOVED PANEL AND REPLACED SEALS. NO FURTHER LEAKS NOTED AT THIS TIME. SUSPECT VIBRATION LOOSENED FASTENERS COMBINED WITH SEAL DETERIORATION CAUSED LEAK.