What was found
EMERGENCY DOORS LIGHT ILLUM WITH EICAS MSG POS 11 (05=L EMER DR , 06=R EMER DR, 11=L WING SLIDE, 12=R WING SLIDE). *S/D* FOUND SENSOR FOR DOOR CLOSED, S218 OUT OF ADJUSTMENT. SHIMMED AND ADJUSTED SENSOR PER MM 52-71-00. REACTIVATED DOOR PER MM 25-65-00. OP CHECKED OK FOR SERVICE.