What was found
STAB TRIM WILL NOT TRIM IN NOSE DOWN DIRECTION WITH CENTER STAB TRIM CUTOUT SWITCH IN NORMAL AND RIGHT STAB TRIM SWITCH IN CUTOUT POSITION. TRIMS NORMALLY WITH TRIM LEVERS. [08-08-07] STABILIZER NOSE DOWN OPERATION STARTED WORKING OKAY AFTER CYCLING STABILIZER WITH ALTERNATE LEVERS. IN THE ALTERNATE ELECTRIC STAB TRIM MODE, THE UP LIMIT IS RESTRICTED TO APPROX.+3.85 DEGREES. PASSED MCDP TEST 65. REPLACED STAB TRAVEL LIMIT AND POSITION TRANSMITTER MODULE.