What was found
FWD GALLEY FLOOR AREA, STA 246 AT RBL 72 AREA, BULKHEAD WALL, LOWER FLOOR CHORD CORRODED UNDER SHEAR WEBBING, FWD EDGE. REMOVED DAMAGED SECTION OF CHORD, RBL 49 TO RBL 72. FABRICATED & INSTALLED SPLICE & REPAIR ANGLES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD GALLEY FLOOR AREA, STA 246 AT RBL 72 AREA, BULKHEAD WALL, LOWER FLOOR CHORD CORRODED UNDER SHEAR WEBBING, FWD EDGE. REMOVED DAMAGED SECTION OF CHORD, RBL 49 TO RBL 72. FABRICATED & INSTALLED SPLICE & REPAIR ANGLES.