What was found
CAPTAIN REPORTED, T/E FLAP DISAGREE ON FINAL. [08-17-07] FSEU BITE CARRIED OUT WITH FLAP HANDLE SET FOR 30 AND READOUT SHOWING 20. THIS CONFIG RESULTED FROM THE FLAP LEVER ROTARY VARIABLE DIFFERENTIAL TRANSFORMER BEING IN MISRIGGED CONFIGURATION & OUTBD SLAT PEDISTAL FLAP CONTROL ROTARY TRANSFORMER ALSO BEING MISRIGGED. SYSTEM RESET BY CYCLING ARMING SW'S, LIGHTS SHOWN AFTER THE BITE CHECK. L, C, R BITE - ALL OK,THEN FLAP OPERATION NORMAL.