What was found
FWD CARGO PIT, FOUND CORROSION ON ANGLE FRAME INSIDE NEXT TO ROLLOUT STOP 3RD FROM MOST FORWARD POSITION AT STA 575. 08-31-07 REMOVED CORROSION VERIFIED MATERIAL LOSS WITHIN LIMIT. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO PIT, FOUND CORROSION ON ANGLE FRAME INSIDE NEXT TO ROLLOUT STOP 3RD FROM MOST FORWARD POSITION AT STA 575. 08-31-07 REMOVED CORROSION VERIFIED MATERIAL LOSS WITHIN LIMIT. OK FOR SERVICE.