As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYD PUMP DEM C2 LOW CENTER HYDRAULIC DEMAND PUMP NR 2 PRESSURE WHEN COMMANDED ON, OR CENTER DEMAND PUMP NR 2 OVERHEATED. 10-05-07 AFTER TROUBLESHOOTING & HISTORY REVIEW, DETERMINED THAT NR 2 CONTROL HYD PUMP OPERATED OK FOR SEVERAL LEGS AFTER PIN D7716B (OF WDM29-11-40) WAS REPOSITIONED. REMOVED CONNECTOR PINS AND RE-PINNED UNIT. TESTED OK FOR SERVICE.