What was found
ABORTED TAKEOFF DUE TO NR 2 ENGINE COMPRESSOR STALL. *S/D* ACP POWER ASSURANCE, ACCEL AND DECEL CHECKS, ACCOMPLISHED POWER ASSURANCE RUNS, ALL PARAMETERS NORMAL, ACCEL 6 SECONDS, DECEL 3 SECONDS, ALL NORMAL NO MESSAGES. ACCOMPLISHED CHECK INSP OF VSV, LUBRICATION OF HP COMPRESSOR VSV RAN ENG ALL PARAMETERS NORMAL.