What was found
AFT PIT STA 1420 MAIN FRAME BETWEEN STR 25L AND 26L HAS 1 DENT. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE & INSTALLED ANGLE REPAIR. INSTALLED NEW STRINGER CLIP AT STA 1420, STR 25L. REPAIR INSTALLED BETWEEN STR 24L & 26L.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT STA 1420 MAIN FRAME BETWEEN STR 25L AND 26L HAS 1 DENT. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE & INSTALLED ANGLE REPAIR. INSTALLED NEW STRINGER CLIP AT STA 1420, STR 25L. REPAIR INSTALLED BETWEEN STR 24L & 26L.