What was found
LT FLAP DID NOT MOVE FROM 1 TO UP POSITION. FLIGHT RETURNED TO DEPARTURE. REMOVED AND REPLACED PROXIMITY SENSORS S282 AND S283 IAW SWPM 20-30-12 AND AMM 27-88-01, BITE TEST PSEU WAS PERFORMED AND IT WAS FOUND NORMAL IAW FIM 32-09-03, FIG 103. FLAP POSITION TRANSMITTER NR 5 WAS REMOVED AND REPLACED IAW MM 27-51-45, PG 201-222, OPS CHECK NORMAL, OVERWEIGHT LANDING INSPECTION WAS ACCOMPLISHED IAW MM 05-51-35 PHASE I, OPTION A, PG 201-203, NO DAMAGES WERE FOUND. (K)