Service difficulty report · Relay · Raythn 390

Difficulty date
June 26, 2008
Submitted
July 18, 2008
Operation
General aviation
Aircraft
N404JM
Make and model
Raythn 390
Aircraft serial
RB167
Aircraft time
444 hours, 405 cycles
Part
Relay
Part number
M835366026L
Condition
Stuck
Location
Starter Gen
Part time
444 hours
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INVESTIGATED PILOT REPORT OF RT ENG STARTER/GEN NOT DISENGAGING FROM START FUNCTION AFTER ENG START. FOUND 80K5 RT ENG START LATCH RELAY STUCK IN START FUNCTION. RT STARTER/GEN TERMINAL COVER AND COOLING AIR INLET DUCT SHOW SIGNS OF OVERHEATING. INSPECTED STARTER/GEN, REPLACED 80K5 RELAY, STARTER/GEN FUNCTIONS NORMAL. HAVE REPLACED NUMEROUS 80K3 AND 80K5 START LATCH RELAYS IN 390 SERIES AC THAT HAVE FAILED WITH SHORT TIS. RECOMMEND MFG INVESTIGATE WHETHER THIS IS A RELAY QC OR DESIGN/INSTALLATION ISSUE. (K)