What was found
AFT CABIN FLOORBEAM CORRODED BS 1016 LBL 8 INCHES-10 INCHES. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED STRAP REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN FLOORBEAM CORRODED BS 1016 LBL 8 INCHES-10 INCHES. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED STRAP REPAIR.