What was found
FWD GALLEY DOOR SURROUND OTBD WEB SUPPORT ANGLE CRACKED AT BS 277 TO 294.5 BETWEEN STR 13R AND 14R. MAJOR REPAIR ACCOMPLISHED: REPLACED ANGLE BTWN STRINGERS 10R & 11R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD GALLEY DOOR SURROUND OTBD WEB SUPPORT ANGLE CRACKED AT BS 277 TO 294.5 BETWEEN STR 13R AND 14R. MAJOR REPAIR ACCOMPLISHED: REPLACED ANGLE BTWN STRINGERS 10R & 11R.