As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT FRAME INBOARD FLANGE IS DENTED AT STA 1500 AND STR 26L. CUT OUT DAMAGE FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07 RPR 5. THIS IS A CAT B ZONE 1 RPR WHICH REQU IRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS TO BEGIN WHEN ACFT REACHES 50,000C AND 12,000C THEREAFTER. CURRENT CYCLES IS 20,636 PER SRM 53-00-07 RPR 5 TABLE II.