What was found
EICAS MSG APU GEN OFF DISPLAYED AND APU GEN OFF LIGHT ILLUM WITH APU RUNNING. APU FIELD OFF LIGHT ON. APU GEN FIELD WOULD NOT RESET, RESET THEN RETRIPPED. FOUND APU GENERATOR FAILED. REPLACED APU GEN, OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EICAS MSG APU GEN OFF DISPLAYED AND APU GEN OFF LIGHT ILLUM WITH APU RUNNING. APU FIELD OFF LIGHT ON. APU GEN FIELD WOULD NOT RESET, RESET THEN RETRIPPED. FOUND APU GENERATOR FAILED. REPLACED APU GEN, OPS CHECK GOOD.