What was found
BEAR STRAP CRACKED AT 2 EACH FASTENER HOLES AT FWD ENTRY DOOR UPPER CUTOUT STA 303.9. LOWER CRACK IS AT STR 10L AND UPPER CRACK IS AT STR 9L. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. INSTALLED REPAIR FILLER & DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BEAR STRAP CRACKED AT 2 EACH FASTENER HOLES AT FWD ENTRY DOOR UPPER CUTOUT STA 303.9. LOWER CRACK IS AT STR 10L AND UPPER CRACK IS AT STR 9L. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. INSTALLED REPAIR FILLER & DOUBLER.