What was found
AFT PIT FRAME DENTED STA 1420 S25L TO 26L. REPAIRED FRAME IAW SRM 53- 00-07 DETAIL III PG 8 FRAME FALLS UNDER THE INSPECTION REQUIRMENTS OF SRM 53-00-07 RPR 5 TABLE II ZONE 3. INSPECTIONS TO BEGIN 1 2000 FLIGHT CYCLES AFTER INSTALLATION AND 11000 FLIGHT CYCLES T HERE AFTER. INSPECTIONS ARE BOTH VISUAL AND NDT. PTC CURRENTLY