What was found
'H' STRAP AT STR 13L HINGE LOCATION BTWN BS 294-303, STRINGER SPLICE CHANNEL CRACKED AT AFT EDGE. MAJOR REPAIR ACCOMPLISHED: REPLACED THE INBD 'H' STRAP, INTERCOSTAL WEB, CLIPS AND ANGLE. INSTALLED FRAME WEB REPAIR DOUBLER.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
'H' STRAP AT STR 13L HINGE LOCATION BTWN BS 294-303, STRINGER SPLICE CHANNEL CRACKED AT AFT EDGE. MAJOR REPAIR ACCOMPLISHED: REPLACED THE INBD 'H' STRAP, INTERCOSTAL WEB, CLIPS AND ANGLE. INSTALLED FRAME WEB REPAIR DOUBLER.