As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT BS 1540, FRAME INBOARD FLANGE DENTED AT STR 24R. REMOVED DAMAGED FABRICATED RPR AND INSTALLED IAW SRM 53-00-07 RPR 5 TABLE II THIS IS A CAT B RPR IN ZONE 1 AND REQUIRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS STARTING AT 50,000 TOTAL FLIGHT CYCLES AND 12,000FC THERE AFTER PER SRM 53-00-07 RPR 5 TABLE II. CURRENT PTC= 14,767