As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT STA 1520 FRAME SPLICE GOUGED BETWEEN STR 22R AND 24R. REMOVED DAMAGE FABRICATED AND INSTALLED RPR PER SRM 53-00-07 RPR 5 TABLE II ZONE 1. RPR IS A CAT B RPR AND REQUIRES SUPPLEMENTAL VISUAL AND NDT INSPECTIONS STARTING AT 50,000 TOTAL FLIGHT CYCLES AND 12,000 FC THERE AFTER. CURRENT FC= 14767